On the opening area Carbon Disulfide (CS 2 ) is on the gas form, because CS 2 have boiling point at about 46 o C at atmospheric condition and CS 2 is a flammable. On the plant that use CS 2 as raw chemicals material and then release CS 2 gas should have waste gas treatment to catch this release gas before the flue gas been through away to the environment. There are several type of CS 2 catch process that is used on waste gas treatment plant, and some of them use CS 2 adsorption plant. CS2 adsorption plant recovers CS 2 from the lean gas using vapor phase adsorption onto activated carbon. The CS 2 laden lean gas stream is passing through the activated carbon (AC) bed in the adsorber where CS 2 gas molecules are adsorbed onto the large surface of AC. The adsorption ceases at the equilibrium point at which the AC can not take up any more of CS 2 . CS 2 recovery starts by desorption of CS 2 gas molecules from the AC and followed by the condensation of CS 2 . Thermal energy