Skip to main content

Portable PH Meter

For field engineer that usually measure a pH of the liquid on the environment that they are founded, they usually use portable pH meter in order can easily to check the pH condition of the liquid flow.

The Model Personal pH/ORP Meter is a highly accurate, portable pH meter for
laboratory and field application. With its self-diagnostic function, the PH meter provides
precise measurement of pH and ORP (oxidation-reduction potential). Measurement
results can be stored and stored data can be checked on the meter display any time. The
PHmeter is of waterproof construction so that it can safely be used outdoors on a rainy day, and can also withstand being accidentally dropped into water.
Some Feature should be own by pH meter equipment:
  • Water resistant case
  • Simple calibration
  • Automatic calibration based on preprogrammed data of standard solutions or manual calibration can be done through simple key operations.
  • Calendar and clock function
  • Internal clock functions allow “one-touch checking” of measurement date and time.
  • Data storage function
  • Up to 300 measured pH values along with their respective solution temperatures, dates and times, can be stored and stored data can be checked on the display any time.
  • Auto power off function
  • The meter will turn off power automatically if not operated during a preset time period.
  • The auto power off time can be user configurable in the range of 1 to 120 minutes in increments of 1 minute. The auto power off function can be disabled, where the meter should be used with care to conserve the batteries.
  • Alarm clock function
  • The meter can issue an alarm signal at a specified time. Even when meter power is turned off, the internal clock can issue an alarm signal.
  • Self-diagnostic function
  • A relevant error message will appear based on the self-diagnostic function.
  • Large, clear LCD
  • A measured pH (mV) value, solution temperature, date and time are clearly viewed on the display.
  • Compact, lightweight, and handy
  • The meter fits comfortably your hand and also stands firm on the table.
For portable pH meter it should cover the following specification.
Measuring range: pH: 0 to 14 pH
ORP: -2000 to 2000 mV
Temperature: 0 to 100oC
Resolution: pH: 0.01 pH
ORP: 0.1 mV (-199.9 to 199.9 mV)
1 mV (-2000 to -200 mV and 200 to 2000 mV)
Temperature: 0.1oC
Repeatability (without sensor):
pH: ± 0.01 pH 61 digit
ORP: ± 1 mV 61 digit
Accuracy (Temperature): ± 0.7oC (0 to 70oC)
                                       ±1oC (above 70oC)
Temperature compensation (glass electrode emf — temperature characteristics):
Automatic compensation (or manual compensation*1)
Solution temperature: 0 to 80oC (or 0 to 100oC*1) (0 to 50oC when a KCl replenish free type sensor and its sensor cable are immersed in water)

Solution conductivity: 50 μS/cm or more
Ambient temperature: 0 to 50oC
Construction: Protection class IP67 (IEC 60529)
Power source: 2x AA batteries (LR6)
Auto power off function (time configurable: 1 to 120 minutes)
Battery life: Approximately 600 hours*2 of continuous use (battery type and operating condition dependent)
Dimensions: Approximately 150(H) x 61(W) x 42(D) mm (not including connector part)
Weight: Approximately 220 g (including batteries)
*1: When a needle type or test tube size pH sensor is used.
*2: When alkaline batteries are used.

Comments

Popular posts from this blog

Removing Iron Rust Using Electrochemical Process

One way to remove iron rust is by electrochemical process. The iron or metal that will be rusted is given a negative charge and the other electrode means that it is positively charged, so the rust will be released from the metal because negative ions will come out of the metal and go to the positive electrode. If the process is continued, the iron may become shiny, not because it is coated in therapy because the surface is partly faded. This is because the iron functions as a negative electrode, where the ions on the surface of the iron will decay and dissolve into the chemical solution. To give an idea of this process, see the following video:

Sodium Sulfite and Sodium Hydrosulfite

Sodium Sulfite Sodium sulfite is a compound that is very easily oxidized. For this reason, it is employed in many cases where a gentle reducing agent is desired, e.g. to bleach wool and silk, as an antichlor after the bleaching of yarns, textile and paper, as a preservative for foodstuffs, and to prevent raw sugar solution from colouring upon evaporation. It is very widely used in the preparation of photographic developer to prevent from oxidation from hydroquinone and other agents. It has a small application in the field of medicine as an antiseptic and as an antizymotic for internal use. About 60% of the total merchant market is in the paper Industries. While merchant capacity is about 145,000 t/year, the paper mills have twice capacity to captive use. The demand for boiler feed water treatment is about 15%. It is use to remove oxygen from water and thus help to prevent corrosion and scale formation. These were four major production in 1891, one of which provided 50% percent of the

Viscose Fiber Production Process

Viscose fiber is a base material for textile industry. The first production of this kind product is in Indian than spread over the Europe and United States also in South Asia Country like in Indonesia. Viscose fiber is produced to anticipate the shortage of natural yarn for raw material to produce yarn in textile industries, beside synthetic yarn as replace natural cotton to produce fabric. This one is a simple drawing of viscose fiber production process . Viscose fiber is used to substitute the using of cotton as raw material for textile industry. Beside of cotton availability will not enough to supply market demand in the future, also cotton just available on harvesting season. If people just depend on cotton to produce textile then people will shortage of raw material to produce textile. Using viscose fiber to fulfill of textile industry will not any shortage raw material, beside the price is lower than cotton, viscose fiber also have better quality compare with synthetic fiber fo